Q1: Special requirements for long-distance oil and gas pipelines?
It is necessary to meet the API 5L PSL2 standard (such as X80 steel grade), and the design pressure is often 10-15MPa. The wall thickness needs to be increased or cold-bent pipes need to be used to adapt to the terrain in mountainous areas. A shut-off valve chamber is set every 20km (RTU remote control). The distance between the cleaning station and the cathodic protection station is ≤100km. Arctic pipelines require -60°C low-temperature toughness (such as DWTT test ≥85%).
Q2: How to prevent scale and leaks in urban water supply networks?
The inner lining of cement mortar or polyethylene (PE) reduces scaling, and the flow rate is controlled at 0.5-2m/s to prevent deposition. Leakage detection uses zone metering (DMA) and noise recorders (the minimum leakage can be identified as 0.1L/s). Ductile iron pipes (DIP) replace gray cast iron to reduce the burst rate. Smart water meters monitor abnormal water use in real time. Trenchless lining repair (CIPP process) is preferred for the transformation of old pipe networks.
Q3: What are the requirements for corrosion resistance of chemical pipelines?
Monel alloy (Ni-Cu) is used for hydrofluoric acid pipelines, carbon steel (passivation film protection) is used for concentrated sulfuric acid, and 316L stainless steel is used for acetic acid. PTFE lining is used to deal with strong corrosive media (such as chlor-alkali industry). Incoloy 800 (nickel-based alloy) is used for high-temperature sections. Flange sealing surfaces require spiral wound gaskets (graphite + stainless steel) to prevent leakage.
Q4: What are the additional safety measures for nuclear power pipelines?
The material requires ASME III nuclear grade certification (such as SA-508 Gr.3 Cl.2). Double wall design + leakage monitoring system (LBB principle). 100% radiographic inspection of welding + process qualification (PQR). Seismic analysis meets IEEE 344 standards. Regular in-service inspection (ISI) including eddy current testing (ET) is carried out during operation.
Q5: What are the laying technologies and challenges of submarine pipelines?
S-type pipelaying vessels are suitable for shallow water (<300m), while J-type pipelaying vessels are used in deep water (e.g. 3000m). External pressure buckling needs to be considered (adding a concrete counterweight layer). 3LPP coating + sacrificial anodes are used for corrosion protection. Repair requires ROV underwater welding or mechanical connectors. Route survey avoids coral reefs and submarine landslide areas.