How to install a valve in a pipeline

1. Pre-installation Inspection

Parameter Verification
Confirm that the valve model and specifications are consistent with the design drawings. Check that the nameplate pressure rating matches the piping system.
Component Integrity
The valve stem rotates freely without binding, the threads are straight and free of defects, the sealing surface is flat and free of cracks, and the disc and seat are tightly seated.
Compatibility Verification
Verify that the gasket and packing materials are compatible with the medium (e.g., corrosive fluids require PTFE).

‌

2. Pressure test (mandatory step)

Test Type‌ ‌Operational requirements‌ ‌Eligibility criteria‌
Strength test‌ The valve is fully open, 1.5 times the nominal pressure is maintained for ≥5 minutes No leakage or plastic deformation of the valve body
‌Tightness test​​​​​​​‌ The valve is fully closed, and the pressure is stabilized at 1.25 times the working pressure. Sealing surface leakage ≤ industry allowable value

 

3. Installation Direction and Position Specifications

Flow Direction Markings
Stop valves and check valves must be installed strictly according to the direction indicated by the arrow on the valve body ("low inlet, high outlet"). Reverse installation will result in loose sealing or failure.
Space Layout
Horizontal pipelines: The valve stem must face upward or tilted ≤45°. The handwheel must not face downward (to avoid operational difficulties and water accumulation and rust).
Overhead pipelines: The valve stem can be installed horizontally and remotely controlled via a vertical chain. The handwheel clearance should be ≥100mm.
Maintenance Space
Allow ≥300mm of operating space around the valve. Heavy valves (e.g., DN200 and above) require a separate support bracket.

Pipeline gate valve​​​​​​​

4. Connection Techniques

Threaded Connections:
Wrap the tape clockwise (facing the threads), leaving 1-2 threads unwound to prevent debris from entering the valve cavity.
Flange Connections:
Tighten the bolts diagonally and gradually. Place the gasket centered. Misalignment can result in seal failure. Welding Valves:
The valve must remain open during welding to prevent thermal deformation and damage to the seals. After welding, cool the valve to below 120°C before closing.

 

5. Operating Mechanism Debugging

Manually rotate the valve three times through its full range to confirm there is no sticking or unusual noise.
Check the lubrication status of the transmission (e.g., gearbox) and that the switch limit markings are clear and accurate.
Automatic valves (e.g., solenoid valves) must be energized to test the signal response and verify linkage with the control system.

 

6. Post-Installation Protection

Apply dustproof film to isolate construction dust. Remove the regulating valve spool for separate protection during pipeline flushing.
Stainless steel valves should be covered with PE film to prevent chloride ion corrosion (especially in coastal areas).

 