Carbon Steel Pipe Supplier-GNEE
- Steel pipe testing-flattening test sample requirements:
The steel pipe samples for the flattening test shall be cut from the steel pipes that have passed the visual inspection. The length of the steel pipe testing sample should be no less than 10mm, but no more than 100mm. When we usually do experiments, we will choose the sample length to be 40mm. The edges of steel pipe test specimens are allowed to be rounded or chamfered by filing or other methods. If the test is carried out on the end of a full-length pipe, a cut shall be made perpendicular to the longitudinal axis of the pipe at a distance of the specimen length from the end of the pipe to a depth of at least 80% of the outer diameter. When cutting the sample, prevent damage to the surface of the sample and change the properties of the steel pipe due to heating or cold processing.

- Steel pipe inspection-flattening test specific steps:
1. When performing the flattening test, the test sample should be placed between two parallel flat plates.
2. Apply pressure evenly to the end of the sample or steel pipe of the specified length in the direction perpendicular to the longitudinal axis of the pipe to flatten it until the distance between the two pressure plates reaches the value specified in the relevant product standards under the action of the force. The distance should be measured under load.
3. In the case of closed flattening, the contact width of the inner surface of the specimen shall be at least 1/2 of the width of the specimen after flattening.
4. When welding steel pipes for flattening tests, the welding seam position should be specified in the relevant standards. If there is no provision, the welding seam should be located at 90° to the direction of force application.
5. The test is usually conducted at room temperature. When the sample is flattened, the moving speed of the pressing plate should not exceed 25mm/min.
6. The length of the pressing plate should exceed the width of the flattened specimen, that is, at least 1.6 times the outer diameter of the tube. The width of the pressure plate should not be less than the length of the specimen. The pressure plate should be sufficiently rigid.
7. After flattening the steel pipe test sample to the specified distance, remove the load and remove the sample. Evaluate the test results in accordance with the requirements of relevant steel pipe product testing standards. If no specific requirements are specified, the specimen without visible cracks after the flattening test shall be assessed as qualified. Only slight cracking at the edge of the specimen shall not be deemed to be scrapped.