Jan 13, 2026 Leave a message

EN 10217 S275 Electric Resistance Welded Pipe

info-259-194info-225-225

EN 10217 S275 Pressure Pipe

Note: S275 is a structural steel grade designation per EN 10025, not typically a grade for pressure tubes per EN 10217. This indicates a potential mix-up in specification.

EN 10217 uses a "P" prefix for pressure tube grades (e.g., P235, P265).

EN 10219 (for structural hollow sections) uses "S" prefix grades like S235, S275, S355.

However, if referring to a pressure tube made from steel with S275-grade properties, it would likely align with EN 10217-1 P265 or similar.


Correct Grade Mapping for Pressure Application

Intended "S275" Closest EN 10217 Grade Key Rationale
Yield Strength ~275 MPa P265 (Min YS = 265 MPa) Nearest match. P265 is the standard grade for this strength level in pressure tubing.
General Purpose EN 10217-1: Welded tubes, non-alloy steel The correct part for standard ERW carbon steel pressure tubes.
Elevated Temp Service EN 10217-2: P265TR1 or P265TR2 If service is above room temperature (up to 300°C or 450°C).

EN 10217-1 P265 ERW Pipe Specification

Mechanical Properties

Property Requirement for P265
Minimum Yield Strength (ReH) 265 MPa (~38,400 psi)
Tensile Strength (Rm) 410 - 570 MPa
Minimum Elongation (A) 22% (based on test piece geometry)

Chemical Composition (Maximum %)

Element P265
Carbon (C) 0.20
Manganese (Mn) 1.20
Phosphorus (P) 0.025
Sulfur (S) 0.020
Silicon (Si) 0.35 (if killed steel)

Manufacturing & ERW Process

Process: High-Frequency (HF) Electric Resistance Welding.

Material: Continuously cast, fine grain killed steel strip/plate.

Weld Treatment: Weld seam may be heat-treated (normalized) to match base metal properties, especially for critical applications.

Testing: Mandatory 100% non-destructive testing of the weld seam (Eddy Current or Ultrasonic).

Standard Dimensions (Typical ERW Range)

Outside Diameter: 21.3 mm to 610 mm (≈ 1/2" to 24")

Wall Thickness: 2.0 mm to 25.0 mm

Lengths: Random or specified cut lengths up to 24m.

Key Tests & Inspection (EN 10217-1)

Hydrostatic Test or NDE Alternative: Proof of leak tightness.

Weld Seam NDE: 100% of weld length by Eddy Current (EN ISO 10893-5) or Ultrasonic (EN ISO 10893-10).

Transverse Tensile Test: On finished tube across the weld.

Flattening Test: On a ring sample across the weld to verify ductility.

Visual & Dimensional Inspection: Per EN 10246 series.

Common Applications

Process piping for water, steam, air, and non-aggressive gases/liquids.

Boiler and heat exchanger tubing (with appropriate temperature grade).

Hydraulic systems.

General mechanical and pressure applications.


Comparison: S275 (Structural) vs. P265 (Pressure)

Aspect S275JR (EN 10025 / EN 10219) P265 (EN 10217-1)
Primary Use Structural (columns, beams, frames) Pressure Containment
Standard Focus Mechanical properties, weldability for construction. Pressure integrity, leak-tightness, elevated temp properties.
Key Test Tensile, bend, impact (Charpy). Hydrostatic/NDE, 100% weld seam inspection, flattening test.
Chemical Control Less strict on S/P (e.g., S≤0.035%). Stricter (S≤0.020%, P≤0.025%) for better formability & integrity.
Certification Certificate 2.2 or 3.1 may be sufficient. Usually requires Inspection Certificate 3.1.B per EN 10204.

Send Inquiry