What A671 CC70 Means
ASTM A671 is the standard for electric-fusion-welded (EFW) carbon steel pipe for atmospheric and lower-temperature service, and CC70 is one of its grades. In the designation, the letters CC identify the base plate specification, ASTM A516 Grade 70, and the number 70 is the minimum tensile strength of the finished pipe in ksi, equal to about 485 MPa. The pipe is made by forming plate into a cylinder and welding the longitudinal seam by automatic submerged arc welding. A671 CC70 is used for large-diameter piping in refineries, power stations, chemical plants, and refrigerated facilities, where a seamless product of the required size is not practical.
The Plate Material
The base plate, A516 Grade 70, is a carbon steel plate for pressure vessels at moderate and lower temperatures, with a minimum yield strength of 260 MPa (38 ksi) for the common thickness range and a tensile range of 485 to 620 MPa. The typical composition limits are about 0.28% carbon maximum, 0.85 to 1.20% manganese, 0.035% phosphorus, and 0.035% sulphur, with silicon 0.13 to 0.45%. The plate is made to a fine-grain killed practice, which gives the toughness that the lower-temperature service requires. The pipe certificate reports the plate heat analysis and the finished-pipe mechanical results.
Heat-Treatment Classes
The class number in the designation defines the heat treatment of the finished welded pipe. The valid classes are 10, 20, 30, 40, 50, 60, 70, and 80: Class 10 is supplied without post-weld heat treatment, and the higher classes add stress relief, normalizing, normalizing and tempering, or quenching and tempering. For the A516-based grades, the post-weld heat-treatment range is about 590 to 680 C, the normalizing temperature is about 925 C, and the quenching and tempering route uses a quenching temperature of about 900 C with tempering at a minimum of 650 C. Class numbers such as 11, 12, or 13 that appear in some market documents are not part of the standard; the class is always one of the ten values.
Manufacturing and Testing
The pipe is formed from plate, and the longitudinal seam is welded by double-sided submerged arc welding. Testing includes tensile testing of the base metal and the weld, guided bend tests of the weld, hydrostatic testing, and non-destructive examination of the longitudinal weld, normally by radiography, with the extent agreed for the service. For lower-temperature duty, Charpy V-notch impact testing is specified at the design temperature, with the service limit of impact-tested grades around -50 F (-45 C). The mill certificate to EN 10204 3.1 or 3.2 documents the plate chemistry, the mechanical results, the heat-treatment records, and the NDE results.
Applications
A671 CC70 pipe is used for large-diameter process and utility piping: refinery transfer lines, petrochemical piping, power-station cooling and steam systems, and refrigerated-gas facilities. The 70 ksi minimum tensile strength gives a lighter wall than the lower grades for the same pressure, and the fine-grain plate provides the toughness needed at lower temperatures. For high-pressure service at moderate temperatures, the companion standard A672 applies, and for cryogenic temperatures below the A671 limit, A333 or austenitic stainless steel is required.
Frequently Asked Questions
Q: What does CC70 mean in A671?
The letters CC identify the base plate per ASTM A516 Grade 70, and 70 is the minimum tensile strength of the finished pipe in ksi (485 MPa).
Q: What classes does A671 define?
Classes 10 to 80 in steps of ten, describing the heat treatment. Class numbers such as 11, 12, or 13 are not part of the standard.
Q: What is the low-temperature limit?
Impact-tested grades cover service down to about -50 F (-45 C); colder service requires A333 or stainless steel.
Q: What plate is used for CC70?
ASTM A516 Grade 70, a fine-grain killed pressure-vessel plate with a minimum yield of 260 MPa.
Q: What tests are required?
Tensile tests of base metal and weld, guided bend tests, hydrostatic testing, radiography or other NDT of the weld, and Charpy impact testing when specified.
Q: What is the difference between A671 and A672?
A671 covers EFW pipe for atmospheric and lower-temperature service; A672 covers the same product family for high-pressure service at moderate temperatures.