Nov 27, 2025 Leave a message

ASTM A500 Square Hollow Sections: Scope, Properties, and Applications

Scope of ASTM A500

ASTM A500 is the standard specification for cold-formed welded and seamless carbon steel structural tubing in round, square, rectangular, or special shapes. The tubing is intended for welded, riveted, or bolted connections in bridges and buildings, and for general structural applications. It is produced in both welded and seamless forms, with a circumference of 88 inches (2235 mm) or less and a specified wall thickness of 1.000 inch (25.4 mm) or less. The standard defines three strength grades, A, B, and C, and the product is known as hollow structural sections (HSS) in North American practice.

Grades and Mechanical Properties

The three grades differ in their minimum yield and tensile strengths:

Grade Minimum yield strength Minimum tensile strength
A 39,000 psi / 270 MPa 45,000 psi / 310 MPa
B 46,000 psi / 315 MPa 58,000 psi / 400 MPa
C 50,000 psi / 345 MPa 62,000 psi / 425 MPa

The minimum elongation is set by the wall thickness for each grade. The strength of the cold-formed section is higher than the as-rolled plate from which it is made, and the standard sets the guaranteed values for design. When a heat-treatment requirement is added to a cold-formed section, it is specified by the purchaser in the order, because the base standard does not mandate heat treatment for the normal grades.

Dimensional Range and Tolerances

The standard covers sections with a circumference up to 88 inches and a wall thickness up to 1.000 inch, in round, square, rectangular, and special shapes. The square hollow section (SHS) is produced in the standard sizes from about 2 by 2 inches up to 12 by 12 inches and larger on special order, with the wall thickness in the decimal series such as 0.188, 0.250, 0.313, and 0.375 inch. Tolerances cover the outside dimensions, the wall thickness, the corner radii, and the straightness, and the section properties for design are taken from the AISC manual or the supplier's tables.

Applications

A500 square tubing is used as primary and secondary structural members in buildings, such as columns, beams, and trusses; in bridges and infrastructure projects, including overpasses and heavy-load supports; in industrial facilities such as factories, warehouses, and power plants; and in transportation equipment such as trailer and truck frames. The closed hollow section gives a high strength-to-weight ratio, a clean appearance, and efficient performance in compression, bending, and torsion, which is why HSS is preferred for exposed steelwork.

Testing and Inspection

The standard requires tensile testing of the finished product, chemical analysis, and the dimensional checks of the sections. The weld seam of welded tube is verified by the flattening test and, where required, by non-destructive examination. Each lot is certified with the grade, the chemical results, and the mechanical property results, and the marking identifies the producer and the specification. For critical projects, additional requirements such as Charpy impact testing can be specified in the order.

A Note on Dynamic Service

The standard cautions that products made to this specification may not be suitable for applications such as dynamic load elements in welded structures where low-temperature notch toughness, typically measured by Charpy impact testing, is important. For such service, the designer should specify a material with guaranteed impact properties, such as the fine-grain structural grades of other standards, and confirm the toughness requirements with the supplier.

Frequently Asked Questions

Q: What is ASTM A500?

The standard for cold-formed welded and seamless carbon steel structural tubing in round, square, rectangular, and special shapes, used in buildings, bridges, and general structures.

Q: What sizes does A500 cover?

Sections with a circumference of 88 inches or less and a wall thickness of 1.000 inch or less, in the standard shapes and sizes.

Q: What are the grades of A500?

Grades A, B, and C, with minimum yield strengths of 39, 46, and 50 ksi and minimum tensile strengths of 45, 58, and 62 ksi.

Q: What is A500 square tube used for?

Columns, beams, trusses, bridge members, industrial structures, and vehicle frames.

Q: Is A500 tubing heat treated?

The normal grades are not heat treated; a heat-treatment requirement is added by the purchaser in the order where it is needed.

Q: Is A500 suitable for dynamic welded structures?

The standard cautions that it may not be suitable where low-temperature notch toughness matters; materials with guaranteed Charpy impact properties should be used in such service.